References

1. Angolkar PV, Arnold JV, Nanda RS, Duncanson MG Jr. Force degradation of closed coil springs: an in vitro evaluation. Am J Orthod Dentofacial Orthop 1992 Aug; 102(2): 127–33. <https://doi.org/10.1016/0889-5406(92)70024-5>
2. Darendeliler MA, Darendeliler H, Üner O. The drum spring (DS) retractor: a constant and continuous force for canine retraction. Eur J Orthod 1997 Apr; 19(2): 115–30. <https://doi.org/10.1093/ejo/19.2.115>
3. Liu SS-Y, Kyung H-M, Buschang PH. Continuous forces are more effective than intermittent forces in expanding sutures. Eur J Orthod 2010 Aug; 32(4): 371–80. <https://doi.org/10.1093/ejo/cjp103>
4. Tripolt H, Burstone CJ, Bantleon P, Manschiebel W. Force characteristics of nickel-titanium tension coil springs. Am J Orthod Dentofacial Orthop 1999 May; 115(5): 498–507. <https://doi.org/10.1016/S0889-5406(99)70271-4>
5. Miura F, Mogi M, Ohura Y, Karibe M. The super-elastic Japanese NiTi alloy wire for use in orthodontics. Part III. Studies on the Japanese NiTi alloy coil springs. Am J Orthod Dentofacial Orthop 1988 Aug; 94(2): 89–96. <https://doi.org/10.1016/0889-5406(88)90356-3>
6. Manhartsberger C, Seidenbusch W. Force delivery of Ni-Ti coil springs. Am J Orthod Dentofacial Orthop 1996 Jan; 109(1): 8–21. <https://doi.org/10.1016/S0889-5406(96)70158-0>
7. Samuels RH, Rudge SJ, Mair LH. A clinical study of space closure with nickel-titanium closed coil springs and an elastic module. Am J Orthod Dentofacial Orthop 1998 Jul; 114(1): 73–9. <https://doi.org/10.1016/S0889-5406(98)70241-0>
8. Samuels RH, Rudge SJ, Mair LH. A comparison of the rate of space closure using a nickel-titanium spring and an elastic module: a clinical study. Am J Orthod Dentofacial Orthop 1993 May; 103(5): 464–7. <https://doi.org/10.1016/S0889-5406(05)81798-6>
9. Bennett JC, McLaughlin RP. Controlled space closure with a preadjusted appliance system. J Clin Orthod 1990 Apr; 24(4): 251–60.
10. Han S, Quick DC. Nickel-titanium spring properties in a simulated oral environment. Angle Orthod 1993 Spring; 63(1): 67–72.
11. Webb RI, Caputo AA, Chaconas SJ. Orthodontic force production by closed coil springs. Am J Orthod 1978 Oct; 74(4): 405–9. <https://doi.org/10.1016/0002-9416(78)90062-3>
12. Maganzini AL, Wong AM, Ahmed MK. Forces of various nickel titanium closed coil springs. Angle Orthod 2010 Jan; 80(1): 182–7. <https://doi.org/10.2319/011509-592.1> <PubMed>
13. Boshart BF, Currier GF, Nanda RS, Duncanson MG Jr. Load-deflection rate measurements of activated open and closed coil springs. Angle Orthod 1990; 60(1): 27–32; discussion 33–34.
14. Záhora J, Bezrouk A, Hanus J. Models of stents – comparison and applications. Physiol Res 2007; 56 Suppl 1: S115–121.
15. Bezrouk A, Hanuš J, Záhora J. Temperature characteristics of nitinol spiral stents. Scripta Medica Facultatis Medicae Universitatis Brunensis Masarykianae 2005; 78(4): 219–26.
16. Wichelhaus A, Brauchli L, Ball J, Mertmann M. Mechanical behavior and clinical application of nickel-titanium closed-coil springs under different stress levels and mechanical loading cycles. Am J Orthod Dentofacial Orthop 2010 May; 137(5): 671–8. <https://doi.org/10.1016/j.ajodo.2008.06.029>
17. Havránek A. Úvod do bioreologie. Praha: Karolinum 2007.
18. Santos ACS, Tortamano A, Naccarato SRF, Dominguez-Rodriguez GC, Vigorito JW. An in vitro comparison of the force decay generated by different commercially available elastomeric chains and NiTi closed coil springs. Braz Oral Res 2007 Mar; 21(1): 51–7. <https://doi.org/10.1590/S1806-83242007000100009>
19. López N, Vicente A, Bravo LA, Calvo JL, Canteras M. In vitro study of force decay of latex and non-latex orthodontic elastics. Eur J Orthod [Internet] 2011 Jan 13 [cited 2012 Jan 27]; Available at: http://www.ncbi.nlm.nih.gov /pubmed/21239396.
20. Hanus J, Nosek T, Zahora J, Bezrouk A, Masin V. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians. Physica Medica [Internet] [cited 2012 Oct 12]; (0). Available from: http://www.sciencedirect.com/science/article/pii /S112017971100158X.
21. Zahora J, Hanus J, Masin V, Bezrouk A. Automated data acquisition and FEM virtual experiments in teaching medical biophysics. Proceedings of the 10th IASTED International Conference on Computers and Advanced Technology in Education, 2008, p. 329–33.
22. Hanus J, Zahora J, Masin V, et al. Computer aided learning and training on the platform of medical information system. Proceedings of the 10th IASTED International Conference on Computers and Advanced Technology in Education, 2008, p. 373–7.