Acta Med. 1998, 41: 135-139

https://doi.org/10.14712/18059694.2019.178

A New Method of Estimation of the Optimal AV Delay by Using Pulse Oximetry in DDD Paced Patients

Miroslav Měšťan, Jiří Kvasnička, Pavel Rejchrt

1st Department of Internal Medicine, Charles University, Faculty of Medicine and Teaching Hospital, Hradec Králové, Czech Republic

Received May 1, 1998
Accepted July 1, 1998

References

1. Haskell RJ, French WJ. Physiological importance of different atrioventricular intervals to improved exercise performance in patients with dual chamber pacemakers, Br Heart J 1989; 61:46-51. <https://doi.org/10.1136/hrt.61.1.46> <PubMed>
2. Nishimura RA, Hayes DL, Holmes DR, Tajik AJ. Mechanism of hemodynamic improvement by dual-chamber pacing for severe left ventricular dysfuction: an acute Doppler and catheterization hemodynamic study. JACC 1995; 25: 281-8. <https://doi.org/10.1016/0735-1097(94)00419-Q>
3. Mitchell JH, Gupta DN, Payne RM. Influence of atrial systole on effective ventricular stroke volume. Circ Res 1965; 17:11-8. <https://doi.org/10.1161/01.RES.17.1.11>
4. Fargel B, Lindvall K. Non-invasive beat-to-beat analysis of stroke volume and digital pulse volume in patients with compete heart block and artificial pacing. Acta Med Scand 1979; 205:185-90.
5. Kvasnička J, Tauchman M, Kovář D, Jandík J, Gajdošová I, Rejchrt P. Atrial contribution to ventricular ejection in sequentially paced patients. Physiol Res 1996; 45:159-63.
6. Yellin EL, Sonnenblick EH, Frater RWM. Dynamic determinants of left ventricular filling: an overview. Cardiac Dynamics. Hague:Martinus Nijhoff Publishers, 1980:145-58.
7. Dvořák L, Sobotka M, Ledvinka P. Famulus 3.5 - příručka uìivatele (user's manual), Jihlava:Wimpy, 1992.
8. Warner HR, Swan HJC, Connoly DC, Tompkins RG, Wood EH. Quantitation of beat-to-beat changes in stroke volume from the aortic pulse contour in man. J Appl Physiol 1953; 5:495-505. <https://doi.org/10.1152/jappl.1953.5.9.495>
9. Warner HR, Rutishauser W. Comparison of beat-to-beat estimates of stroke volume from aortic pressure with flowmeter estimates (abstr.). Physiologist 1965; 8:299.
10. Eliakim M, Sapoznikov D, Wienman J. Assessment of the atrial contribution to cardiac performance by a noninvasive photoplethysmographic technique. Cardiology 1973; 58:7-13. <https://doi.org/10.1159/000169614>
11. Kvasnička J, Měšťan M, Tauchman M et al. Síňový příspěvek a optimální hodnota AV intervalu u sekvenčně stimulovaných nemocných. Vnitr Lek 1997; 43:340-4.
front cover

ISSN 1211-4286 (Print) ISSN 1805-9694 (Online)

Open access journal

Archive